Skip to content
AU delivery 12 weeks · Financing on request
24/7 contact and support +61 485 040 545 Contact
Hard-shell · Lay-down · One person

Altura One

The restorative lay-down chamber.

Lie flat in a stainless steel cabin, with two windows for a view the whole session. Standard Oxygen is made on board, and Advanced Oxygen can be specified when you order.

Hardware from AUD 99,900 — delivered & installed.

Choose your oxygen, leather and finish, then send the build with your quote request. Or book a 15-minute call, text, email or phone us.

No tanks, no refills
Oxygen is made on board
≈ 3.5 × 1.9 m
Floor space, with clearances
10A
Standard power points
Up to 2.0 ATA
In sealed steel
Walkthrough

See Altura One in motion.

Filmed inside the cabin: the control screen, the windows, and what lying flat in it actually looks like.

Altura One walkthrough
Advanced Oxygen

Step up to sealed-mask oxygen.

Altura One ships with Standard Oxygen. Choose the Advanced Oxygen (BIBS) upgrade when you order and a demand-valve mask delivers high-purity oxygen, with exhalation routed outside the chamber.

BIBS · 95–98% O₂ · demand valve

The sealed Advanced Oxygen mask and its breathing hoses
The chamber

Lay flat. Look out.

  • Two windows
  • Hard-shell pressure
  • Climate control
  • Touchscreen
  • Pre-built protocols
  • Safety valves
Altura One in white from a three-quarter angle, the hatch open and the touchscreen inside
Standard

Two large viewing windows

Open external sightline through every session, lying flat. Built to be looked out of, not sealed off from. The reason buyers pick lay-down with Altura.

Altura One hard-shell lay-down chamber in white, the sliding hatch closed
Standard

304 stainless cabin

2.5mm 304 stainless steel cabin with a 10mm polycarbonate door. Built like equipment, finished like furniture, for the decade-plus install.

Glacier leather swatch, quilted
Standard

Premium leather interior

Six leather colours, all included, with Glacier white as standard. Comfort-forward fit-out for longer sessions.

Altura One from the end: the round shell, the cabin and the bed inside
Standard

Cabin air conditioner

A cabin air conditioner comes with the chamber, so long sessions stay even-temperature.

The touchscreen control panel inside the Altura One cabin
Standard

Touchscreen with pre-built protocols

HQO2 Protocol Technology™ runs pre-built protocols from the chamber's touchscreen, from inside the cabin. Custom protocols are available as an upgrade.

The sealed Advanced Oxygen mask and its breathing hoses
Upgrade

BIBS · Advanced Oxygen

Demand-valve mask delivery at 95–98% oxygen efficiency. Sealed mask, exhalation routed outside the chamber.

Specifications

The numbers.

Type
Monoplace hard-shell · lay-down
Pressure
1.3 – 2.0 ATA
Capacity
1 person
Oxygen system
Continuous flow · 93–96% standard · BIBS Advanced Oxygen 95–98% available as upgrade
Footprint
0.90 × 2.20 m
Dimensions
900 × 2200 mm cabin (D × L) · 304 stainless steel · 10mm polycarbonate door
Warranty
2 years, parts & labour

Full technical specifications, weight, material, noise level, concentrator flow, available on request.

  • The longer-session protocol user. 75–90 minute dwells, audio or sleep through sessions. Lay-down format earns its keep when session length matters.
  • The restoration-led buyer. Recovery and sleep are the headline outcomes. The horizontal posture matches the use case.
  • The lay-down user who wants a view. Wants to see the room through the session, not stare at a ceiling — two large cabin windows give session-long external sightline.
Quality assured

Certifications & standards.

Built to international manufacturing standards: trust, safety, quality and reliability.

Built to ASME code

Built to ASME code

Boiler & Pressure Vessel Code

A chamber is a pressure vessel with a person inside it. The reference standard for that is the ASME Boiler and Pressure Vessel Code, and the vessel is engineered to it.

ISO-certified facilityISO-certified facilityISO-certified facility

ISO-certified facility

9001 · 14001 · 13485

Quality management (9001), environmental management (14001), and 13485, the medical-device quality standard. Independently audited.

CE Marked

CE Marked

European Conformity

Compliance with European health, safety and environmental-protection standards.

The chamber, drawn

Altura One, inside and out.

The shell, the cabin and the bed, drawn from the chamber itself. Every dimension is from the spec sheet.

X-ray line drawing of Altura One from the end: the round steel shell, the bed and cabin inside, the base and castors 900 mm (cabin) 900 mm
X-ray line drawing of Altura One from the side: the long cylinder, the sliding hatch and window, the bed inside, the base and castors 900 mm (cabin) 2200 mm
We confirm your delivery path and floor on the call.
Chamber
Hard-shell · lay-down · one person
Pressure
1.3–2.0 ATA
Oxygen
Continuous flow, 93–96% purity BIBS mask, 95–98% (upgrade)
Cabin, L × W × H
2200 × 900 × 900 mm
Weight
180 kg
Controls
HQO2 Protocol Technology™
Noise
Up to 62 dB
Power
Standard 10A power points BIBS: O₂ unit on 15A
Warranty
2 years, parts & labour

Hardware from AUD 99,900 — delivered & installed.

Make it yours

Design your Altura One.

Start with the build. Choose your oxygen, leather and finish, then send the build with your quote request. We confirm upgrade pricing in your custom quote.

Altura One in white from a three-quarter angle, the hatch open and the touchscreen inside
Exterior · White

Exterior · Side · End · Controls

Oxygen Pick one
Protocols Optional
Interior leather Pick one
Exterior Pick one
Cabin extras Optional

Your Altura One

Starting build

Oxygen
Standard Oxygen
Protocols
Pre-built protocols
Interior leather
Glacier leather
Exterior
White
Cabin extras
None

Hardware from AUD 99,900 — delivered & installed.

Upgrades are confirmed in your quote. We check your space and delivery on the call, then send final pricing.

Will it fit

Plan the room.

Altura One, its oxygen & pressure unit and its air conditioner, drawn to scale. Measure your room against it, then send us the numbers.

Plan view · to scale 3D view · heights to scale
1232200 mm900≈ 3.5 m (3530 mm)≈ 1.9 m (1900 mm)1 metre
123≈ 3.5 m≈ 1.9 m1 m
  1. Chamber · 2200 × 900 mm
  2. Oxygen & pressure unit · 420 × 760 mm
  3. Air conditioner · 410 × 320 mm
  4. 1.0 m clear in front of the door
  5. Example room 4.2 × 3.0 m · 1 m grid
Chamber900 mm (cabin)Oxygen & pressure unit725 mm tallAir conditioner570 mm tall
123
  1. Chamber · 900 mm (cabin)
  2. Oxygen & pressure unit · 725 mm tall
  3. Air conditioner · 570 mm tall

Example layout, shown with Standard Oxygen. We confirm your room on the call.

≈ 7 m²
Floor area to allow
1.0 m
Clear in front of the door
180 kg
Chamber, the heaviest unit
Path in
Delivered as one piece. The cabin is 900 mm wide and 2,200 mm long, so we confirm the route in before install.
Power
Standard 10A power points near the chamber. With Advanced Oxygen, the oxygen unit needs a 15A circuit, arranged by your electrician.
In the box
The chamber, the oxygen & pressure unit (concentrator and compressor, 68 kg) and the air conditioner unit (36.4 kg). Delivery, installation and operator training are included.
Air
Allow a 200 mm gap around the oxygen & pressure unit and the air conditioner for airflow.
Download the fit-out guide (PDF)
Technical details

Operating & electrical specifications.

Everything Altura One needs on-site: components, power and cabin features. Share this section with your electrician or installer ahead of delivery.

Operating Components

Oxygen & Pressure Unit
Contains
Concentrator and compressor
Dimensions
760 × 420 × 725 mm
Net Weight
68 kg
Oxygen Flow
10 L/min
Oxygen Purity
93–96% standard · 95–98% with BIBS upgrade
Power
220–240V / 1,200W (or 110V / 1,400W)
Air Conditioner
Dimensions
410 × 320 × 570 mm
Weight
36.4 kg
Supplied
With the chamber, as its own unit

Chamber & Electrical

Chamber Cabin
External Dimensions
900 × 2,200 mm (D × L)
Cabin Door
560 × 755 mm · 10mm polycarbonate
Cabin Material
304 stainless steel · 2.5mm
Net Weight
180 kg
Operating Pressure
1.3 – 2.0 ATA (up to 100 kPa)
Pressurised Flow Rate
72 L/min
Boosting Time
17 minutes
Pressure Relief
100 seconds (max rate)
Noise
≤ 62 dB
Electrical Requirements
Voltage
220–240V (AU standard)
Total System Power
2,300–2,500W (cabin) + 1,200W (oxygen & pressure unit)
Outlets
Standard AU 10A power points (BIBS oxygen unit on a 15A circuit)

Cabin Features

Interior
Finish
Leather in six included colours: Glacier (standard), Oat, Graphite, Ember, Azure, Onyx
Exterior Colour
White or Black · premium paint in Blue or Matte black (upgrade)
Lighting
Ambient cabin LED
Climate
Cabin air conditioner (its own unit, included)
Communication
2-way intercom + headset
Controls
Internal touchscreen control panel
Exterior
Controls
External barometer + control panel
Communication
2-way intercom
Safety
Automatic + emergency pressure relief valves
Power

Altura One runs on standard 10A power points near the chamber. With Advanced Oxygen, the oxygen unit needs a 15A circuit, which your electrician arranges; we coordinate with them ahead of install. No structural work required.

Lead Time

12 weeks ex-factory + 3 weeks shipping (~15 weeks total to install). Confirmed in your custom quote.

Download the Space & Fit-Out Guide (PDF)
Talk to an expert

Rather talk it through?

Your build comes with you, whichever way you get in touch.

Altura One hard-shell lay-down chamber in white, the sliding hatch closed
  • Quick delivery
  • Full warranty
  • Precision engineered
Request your quote

Tell us what you're building.

We'll confirm your configuration, your space and your delivery details, then send final pricing.